Orto alresa Digtor 22 C Benchtop Centrifuge
Speed: ≤3000 rpm, Relative Centrifugal Force: ≤2425 x g
The Digtor 22 C is used for oil and gas separation, and can also be used for sediment and condensate analysis. The rotor can use 6-inch and 8-inch tubes and 28 finger tubes.
> Capacity: ≤4 x 100mL (8/6”); Centrifugal Force/Speed: ≤2425xg / 3000rpm
> Complies with: ASTM D 91, D96, D 893, D 1796, D2273, D2709, D 2711, D 4007, D 5546, API 2542, API 2548, BS 4385, ISO 3734, ISO 9030, IP75, IP 359, NF M07-020, DIN 51793
> Centrifuge tubes upright in non-centrifugal state
> GRS: Vacuum system (optional), pre-installed
Features: TFT color display, viewable from over 3m
> Displays rpm/RCF, time, acceleration/deceleration digital (PCBS) with unbalanced positioning function (ULS)
> Speed control, stepwise 10rpm/10xg
> Real-time RCF display function based on actual usage accessories
> Countdown or forward timing function, reaching the set rpm/RCF timing function to ensure experimental reproducibility
> Timer program setting from 1min-99h, in 1s increments, with step and stop program functions
> PCBS function: Progressive control acceleration and braking system with up to 175 selectable slopes to prevent homogenization of separated samples
> ULS function: In case of unbalanced conditions, the unbalanced position number of the rotor will be directly displayed
> 40 program memory sets with password protection
> Different prompt sounds and screen information prompts, real-time display of equipment operation status
Heating
> With preheating program function, preset temperature preheating can be performed after rotor loading
> Temperature range RT+5℃ - 80℃, in 1℃ increments, freely switchable between Celsius and Fahrenheit
> Temperature sensor inside the cavity, with over-temperature protection
> Internal insulation material to prevent heat loss
Anquan
> Anquan system for centrifuge lid
- Automatic lid locking, double mechanical lock
- Emergency lid unlocking function
- Lid locking protection during operation
- Protection against sudden lid drop
- Inspection hole on the lid for operational checks
> Automatic shutdown upon unbalanced check
> Anquan protective layer between the centrifuge chamber and outer shell
> Stainless steel centrifuge chamber (easy to clean)
> Removable rotor when lid is closed
> Both rotor and adapter are autoclaved, easy to install
> Forced internal airflow reduces temperature rise
> Green setting with automatic power-off option
Easy to use
> Microcomputer program control
> Brushless maintenance-free motor
> Rotor and adapter memory function
> Noise level below 60dB
> Start, stop, lid opening, and instant centrifugation functions
> Speed adjustment via rpm/RCF during operation
> Automatic lid opening can be programmed
> Automatic memory of last parameter settings
> Automatic head-turn detection, overspeed protection
EU Certifications: 2011/65/EU, 2012/19/EU, 2014/30/EU, 2014/35/EU, 98/79/EC
Standards Implemented: EN 61010-1, EN 61010-2-020, EN 61326-2-6, EN 61326-1, EN 61010-2-010.