Polarimeters with circulation thermostat temperature control
MEASUREMENT RANGE:±90°±259 °Z
Polarimeters for the laboratory
The polarimeter models P8000-T and P8100-T will allow for a circulation thermostat temperature control in the range between 8 °C and 40 °C when combined with temperature controlled measurement tubes and a thermostat. That makes them suitable for high-precision measurements in quality control. Especially if a multitude of different temperature controlled measurement tubes are to be used, the P8000-T and P8100-T are the right choice. We offer a very large selection of this type of tubes.
* Temperature measurement directly inside the sample
* Accurate, homogeneous water bath temperature control
* Large selection of temperature-controlled measurement tubes
* Quick coupling system for an easy measurement tube change
* Highest accuracy over the entire measurement range
* Very short measurement time of approx. 1 s
* Measurement up to an optical density of 3.0 OD
* Intuitive operation via touch-screen display
* Predefined scales (opt. rotation, spec. rotation, int. sugar scale, concentration)
* Any number of freely definable scales with conversions based on tables or formulas
* Chemical-resistant materials
* Compliance with GMP/GLP, 21 CFR Part 11, Pharmacopeia (USP, BP, JP, Ph. Eur.), FDA, ISO, HACCP, OIML, ASTM, ICUMSA, NIST
Typical applications
The P8000-T polarimeters can be used for a variety of applications in the pharmaceutical, chemical, sugar, food and beverage industry, as well as for the production of flavors and fragrances.
* Determination of concentrations in raw materials, preliminary, intermediate and end products
* Purity control
* Determination of the stereochemical composition and mutarotation
* Monitoring of chemical processes
* Routine analysis with high sample throughput
Model specifications
|
|
P8000-T |
P8100-T |
|
MEASUREMENT DATA |
||
|
SCALES |
Optical rotation [°] |
|
|
MEASUREMENT RANGE |
±90° |
|
|
MEASUREMENT ACCURACY |
±0.003° |
±0.002° |
|
RESOLUTION |
0.001° |
|
|
MEASUREMENT PERIOD ±90° |
Approx. 1 s |
|
|
LIGHT SOURCE |
1 LED with filter |
|
|
WAVELENGTH |
589 nm |
|
|
TEMPERATURE DATA |
||
|
TEMPERATURE CONTROL |
With Circulation Thermostat PT31/PT80 and temperature-controlled measurement tube |
|
|
TEMPERATURE CONTROL RANGE |
PT31: 8-35 °C | PT80: 5-80 °C |
|
|
TEMPERATURE CONTROL ACCURACY |
±0.2 °C |
|
|
TEMPERATURE MEASUREMENT |
With temperature probe PRT-E or PRT-T |
|
|
TEMPERATURE MEASUREMENT RANGE |
0–99.9 °C |
|
|
TEMPERATURE MEASUREMENT RESOLUTION |
0.1 °C |
|
|
TEMPERATURE MEASUREMENT ACCURACY |
±0.1 °C |
|