HACH

HACH TU5300sc Low Range Laser Turbidimeter, EPA Version, Automatic Cleaning Module, Flow, with SC4500 Controller, 1 Ch PN.LXV525.CNKTO012

HACH TU5300sc Low Range Laser Turbidimeter, EPA Version, Automatic Cleaning Module, Flow, with SC4500 Controller, 1 Ch PN.LXV525.CNKTO012

常规价格 $6,499.92 USD
常规价格 促销价 $6,499.92 USD
促销 售罄

* Please consult before ordering

The EPA approved TU5 Series® platform employs a unique optical design that sees more of your sample than any other turbidimeter, delivering the best low level precision and sensitivity while minimizing variability between measurements. For the first time you will be able to remove uncertainty of which measurement to trust between your lab and process instruments, thanks to identical 360° x 90° Detection® Technology in any TU5 Series turbidimeter.

The TU5300sc Low Range Laser Turbidimeter dramatically reduces the time needed to get a turbidity measurement you can rely on. A stable laser light source eliminates the need for annual lamp replacements. The turbidimeter’s measurement surface area has been reduced by 98%, allowing you to save time cleaning. An automatic cleaning module is available that keeps your instrument clean, reducing the amount of time spent cleaning the instrument ever further. All of this, along with the ability to measure to 2 mNTU, gives you the next standard in the evolution of turbidity.

Only the new TU5 Series Lab & Process Turbidimeters with 360° x 90° Detection deliver unprecedented confidence that a change in your reading is a change in your water.

Applications:

  • Filtration
  • Membrane Protection
  • Regulations
  • Water Reuse

Benefits

Groundbreaking 360° x 90° Detection Technology

The TU5 Series employs a patented optical design that sees more of your sample than any other turbidimeter, delivering the best low level precision and sensitivity while minimizing variability from test to test.

Everything about turbidity – faster

The TU5 Series dramatically reduces the time needed to get a turbidity measurement you can rely on, with 98% less online sample surface area to clean, sealed vials for calibration, and the elimination of the need for indexing and silicone oil in the lab. Not to mention, a smaller online sample volume means you will detect events almost immediately.

Easy Adoption

The familiar experience of a modern touchscreen, the ability to use your current Hach sensors, and the same footprint as the SC200, make installation and integration of the SC4500 Controller seamless.

No Time for Downtime

The SC4500's built-in predictive diagnostic software ensures measurement confidence and reduces the risk of unexpected equipment downtime by enabling proactive maintenance planning via MSM, including step-by-step instructions.

Specifications

 

Technical Attributes

Accuracy ±2% or 0.01 NTU from 0 - 40 NTU
±10% of reading from 40 - 1000 NTU based on Formazin primary standard
Cable Length 1.6 m (5.25 ft), extendable up to 50 m (164 ft) for instrument without accessories
Calibration Method For Formazin and Stablcal®:
20 NTU from 0 to 40 NTU; at 20 FNU and 600 NTU for full range

Custom calibration for up to 6-point calibrations
Certifications CE compliant
US FDA accession number: 1420493-000 EPA version, 1420492-000 ISO version
Australian ACMA Marking
Communication None
Controller 1 Channel, 100-240 VAC
Dimensions (H x W x D) 249 mm x 268 mm x 190 mm
Enclosure Rating Electronic compartment IP55; all other functional units IP65 with process head/ACM attached to the TU5300sc/TU5400sc instrument
Fitting Type Sample quick connector: ¼-in. for ¼-in. tubing
Instrument With Flow Sensor and Automatic Cleaning Module
Light Source Class 2 laser product, with embedded 650 nm (EPA 0.43 mW) or Class 1 laser product, with embedded 850 nm (ISO), max. 0.55 mW (complies with IEC/EN 60825-1 and to 21 CFR 1040.10 in accordance with Laser Notice No. 50)
Material ASA Luran S 777K / RAL7000, TPE RESIN Elastocon® STK40,
Thermoplastic Elastomer TPS-SEBS
Model TU5300sc
Mounting Configurations Wall Mount
Operating Humidity Relative humidity: 5 - 95% at different temperatures, non-condensing
Operating Temperature Range 0 - 50 °C (32 - 122 °F)
Options Process Head, Flow Sensor, & Automatic Cleaning Module
Range EPA:
0 - 700 NTU / FNU / TE/F / FTU
0 - 100 mg/L
0 - 175 EBC

ISO:
0 - 1000 NTU / FNU / TE/F / FTU
0 - 100 mg/L
0 - 250 EBC
Regulatory EPA
Repeatability Better than 1% of reading or ±0.002 NTU (TU5300sc) or ±0.0006 NTU (TU5400sc) on Formazin at 25 °C (77 °F), whichever is greater
Resolution 0.0001 NTU / FNU / TE/F / FTU / EBC
Response Time TU5300sc: T90 <45 seconds at 100 mL/min
TU5400sc: T90 <30 seconds at 100 mL/min
Sample Flow Rate 100 - 1000 mL/min; optimal flow rate: 200 - 500 mL/min
Sample Pressure 6 bar (87 psi) maximum, compared to air at sample temperature range from 2 - 40 °C (35.6 - 104 °F)
Sample Temperature 2 - 60 °C (35 - 140 °F)
Signal Average Time TU5300sc: 30 - 90 seconds
TU5400sc: 1 - 90 seconds
Storage Conditions -40 - 60 °C (-40 - 140 °F)
Stray Light <10 mNTU
Units NTU, FNU, TE/F, FTU, EBC
Verification Liquid: Stablcal®, Formazin (0.1 - 40 NTU)
Dry: Glass Rod at <0.1 NTU
Weight 5.95 lbs. (2.7 kg); 11 lbs. (5.0 kg) with all accessories
What's included? Controller, Non-Claros + Embedded Prognosys, without power cord; includes mounting hardware