HACH TU5 Series® TU5300sc Low Range Laser Turbidimeter with Flow Sensor, Automatic Cleaning, and System Check, ISO Version PN.LXV445.99.51122
HACH TU5 Series® TU5300sc Low Range Laser Turbidimeter with Flow Sensor, Automatic Cleaning, and System Check, ISO Version PN.LXV445.99.51122
无法加载取货服务可用情况
* Please consult before ordering
Compliant with ISO Method 7027-1 and perfect for conventional filtration and other low range turbidity measurements, the TU5300sc employs a patented optical design that sees more of your sample than any other turbidimeter, delivering the best low level precision and sensitivity while minimizing variability between measurements. For the first time you will be able to remove uncertainty of which measurement to trust between your lab and process instruments, thanks to identical 360° x 90° Detection® Technology in any TU5 Series® turbidimeter.
The TU5300sc Low Range Laser Turbidimeter dramatically reduces the time needed to get a turbidity measurement you can rely on. With a 10mL sample size, response time is over 15 times faster than a 1720E. A stable laser light source eliminates the need for annual lamp replacements. The turbidimeter’s measurement surface area has been reduced by 98%, allowing you to save time cleaning.
All of this, along with the ability to measure to 0.002 FNU, gives you the next standard in the evolution of turbidity.
A flow meter is included with this turbidimeter that continuously measures flow through the instrument and displays the flow value on screen. Current flow can be output to SCADA via 4-20mA or digital communications.
Ensure that your turbidimeter is always functioning properly with this TU5's System Check capability. With the ability to provide information on measurement status and vial cleanliness, you can have full confidence in your turbidity measurement.
Cleaning your turbidimeter takes valuable time that your staff could use to complete other tasks. The TU5 Series' automatic cleaning module that is included with this instrument completes cleaning for you, saving operator time and money.
Applications:
- Filtration
- Membrane Protection
- Regulations
- Surface Water
- Water Reuse
Benefits
Groundbreaking 360° x 90° Detection Technology
The TU5 Series employs a patented optical design that sees more of your sample than any other turbidimeter, delivering the best low level precision and sensitivity while minimizing variability from test to test.
Matching lab and online results
For the first time you will be able to remove the uncertainty of which measurement to trust, thanks to identical 360° x 90° Detection Technology in both instruments.
Everything about turbidity – faster
The TU5 Series dramatically reduces the time needed to get a turbidity measurement you can rely on, with 98% less online sample surface area to clean, sealed vials for calibration, and the elimination of the need for indexing and silicone oil in the lab. Not to mention, a smaller online sample volume means you will detect events almost immediately.
No surprises
Prognosys™ monitors your TU5 Series online instrument, proactively alerting you to maintenance needs before your measurement becomes questionable. And a Hach Service Agreement protects your investment and helps ensure that you stay in compliance and on budget.
Specifications
Technical Attributes
Accuracy | ±2% or 0.01 NTU from 0 - 40 NTU ±10% of reading from 40 - 1000 NTU based on Formazin primary standard |
Cable Length | 1.6 m (5.25 ft), extendable up to 50 m (164 ft) for instrument without accessories |
Calibration Method | For Formazin and Stablcal®: 20 NTU from 0 to 40 NTU; at 20 FNU and 600 NTU for full range Custom calibration for up to 6-point calibrations |
Certifications | CE compliant US FDA accession number: 1420493-000 EPA version, 1420492-000 ISO version Australian ACMA Marking |
Communication | System Check |
Controller | Sensor Only |
Controller Compatibility | SC4500, SC1000, SC200 |
Dimensions (H x W x D) | 249 mm x 268 mm x 190 mm |
Enclosure Rating | Electronic compartment IP55; all other functional units IP65 with process head/ACM attached to the TU5300sc/TU5400sc instrument |
Fitting Type | Sample quick connector: ¼-in. for ¼-in. tubing |
Instrument | With Flow Sensor and Automatic Cleaning Module |
Light Source | Class 2 laser product, with embedded 650 nm (EPA 0.43 mW) or Class 1 laser product, with embedded 850 nm (ISO), max. 0.55 mW (complies with IEC/EN 60825-1 and to 21 CFR 1040.10 in accordance with Laser Notice No. 50) |
Lower Limit of Detection (LOD) | 0.002 NTU |
Material | ASA S 777K / RAL7000, TPE RESIN Elastocon® STK40, Thermoplastic Elastomer TPS-SEBS |
Model | TU5300sc |
Mounting Configurations | Wall Mount |
Operating Humidity | Relative humidity: 5 - 95% at different temperatures, non-condensing |
Operating Temperature Range | 0 - 50 °C |
Options | Process Head with Flow Sensor and Automatic Cleaning Module |
Power Requirements (Voltage) | None |
Range | ISO: 0 - 1000 NTU / FNU / TE/F / FTU 0 - 250 EBC |
Regulatory | ISO |
Repeatability | Better than 1% of reading or ±0.002 NTU on Formazin at 25 °C (77 °F), whichever is greater |
Resolution | 0.0001 NTU / FNU / TE/F / FTU / EBC |
Response Time | T90 <45 seconds at 100 mL/min |
Sample Flow Rate | 100 - 1000 mL/min; optimal flow rate: 200 - 500 mL/min |
Sample Pressure | 6 bar (87 psi) maximum, compared to air at sample temperature range from 2 - 40 °C (35.6 - 104 °F) |
Sample Temperature | 2 - 60 °C (35 - 140 °F) |
Signal Average Time | 30 - 90 seconds |
Storage Conditions | -40 - 60 °C (-40 - 140 °F) |
Stray Light | <10 mNTU |
System Check | Yes |
Units | NTU, FNU, TE/F, FTU, EBC |
Verification | Liquid: Stablcal®, Formazin (0.1 - 40 NTU) Dry: Glass Rod at <0.1 NTU |
Warranty | 12 months |
Weight | 5.95 lbs. (2.7 kg); 11 lbs. (5.0 kg) with all accessories |
What's included? | TU5300sc Turbidimeter, Automatic Cleaning Unit, User Manual, Wall Mount, Vial Replacement Tool, Screw Set, Drying Cartridge, Flow Regulator, Service Bracket, Flow Sensor |