跳至产品信息
1 / 1

HACH

HACH Solitax highline sc Turbidity (0.001-4000 NTU) and Suspended Solids (0.001-500 g/L) built-in probe, w/o wiper, stainless steel PN.LXV424.99.02200

HACH Solitax highline sc Turbidity (0.001-4000 NTU) and Suspended Solids (0.001-500 g/L) built-in probe, w/o wiper, stainless steel PN.LXV424.99.02200

常规价格 ¥55,626.40 CNY
常规价格 ¥69,533.00 CNY 促销价 ¥55,626.40 CNY
促销 售罄

* Please consult before ordering

High-precision in pipe turbidity and suspended solids measurements in high concentrated sludges according to DIN EN ISO 7027 and DIN 38414

The Solitax highline sc turbidity and suspended solids insertion probe provides high-precision results in clear to strongly turbid liquids as well as in high concentrated sludges. Since this probe is for in pipe use only an appropriate mounting assembly for insertion application is required. Turbidity measurement performance is certified to MCERTS regulation and the probe operates with a 90° measuring method according to DIN EN ISO 7027. The suspended solids measurement by a colour-independent method with an infrared duo scattered light photometer is in accordance with DIN 38414. The Solitax highline sc probe material is stainless steel and measurement data is displayed and processed with the help of a digital Hach SC200 or SC1000 controller.
Furthermore, the Solitax highline sc turbidity immersion probe is compatible for Prognosys which is a predictive diagnostic system that allows you to be proactive in your maintenance, by alerting you to upcoming instrument issues. Know with confidence whether changes in your measurements are due to changes in your instrument or your water.

This instrument connects to Claros, Hach’s innovative Water Intelligence System, enabling you to seamlessly connect and manage instruments, data, and process – anywhere, anytime. The result is greater confidence in your data and improved efficiency in your operations. To unlock the full potential of Claros, insist on Claros Enabled instruments.

Benefits

Certified measurements according to DIN EN ISO 7027 and DIN 38414

Turbidity measurement performance certified to MCERTS regulation and according to DIN EN ISO 7027. The Suspended solids measurement is in accordance with DIN 38414.

No calibration required

Long-term calibration stability since time-consuming multipoint calibrations with dilution series are replaced by a single correction factor.

Excellent correlation to laboratory analysis

Comparisons between laboratory analysis and continuous suspended solids measurement using SOLITAX sc sensors show an exceptional correlation to mixed liquor, settled and thickened sludge. Online measurement not only saves time on manual analysis but also provides critical real time TSS measurements that can be used to operate the plant more efficiently.

Compatible with Hach SC controller platform

Measurement data is displayed and processed with the help of a digital Hach SC200 or SC1000 controller.

For in pipe use only!

An appropriate mounting assembly for insertion application is required.

Combinable with probes for O2, NO3, pH, etc

Specifications

 

Technical Attributes

Accuracy Turbidity up to 1000 NTU:
without calibration < 5% of the measured value ±0.01 NTU
with calibration < 1% of the measured value ±0.01 NTU
Automatic Wiper No
Body Material Stainless Steel
Cable Length 10 m (33 ft) (optional extension cables available)
Calibration Method Turbidity: Formazin or Stablcal Standard (at 800 NTU).
Suspended Solids: Sample specific, based on gravimetric TSS analysis with a correction factor procedure.
Certifications CE, MCERTS
Controller Sensor only
Controller Compatibility SC4500, SC1000, SC200
Diameter Sensor 60 mm
Flow Max. 3 m/s (the presence of air bubbles affects the measurement)
Length 315 mm
Maintenance Interval 1 h/month
Material Wiper: Silicon
Sensor body: Stainless steel 1.4571
Max. cable length Sensor-to-Controller 100
Measuring Principle Infrared Duo scattered light technique for color-independent
turbidity measurement Turbidity in accordance with
DIN EN ISO 7027 / TS equivalent DIN 38414
Model Solitax highline sc
Mounting Insertion
Operating Temperature Range 0 - 40 °C (32 - 104 °F)
Parameter High Range Suspended Solids, Turbidity
Pressure Range Stainless steel insertion sensor: <6 bar or <60 m
Range TSS-content: 0.001 - 500 g/L; 0.001 - 500,000 mg/L (the upper range is dependent on the sample property)
Turbidity: 0.001 - 4000 NTU
Repeatability TSS content: < 3%|Turbidity: < 1%
Response Time T90 1 - 300 s adjustable
Special Notes Installation note:
Distance sensor-wall
> 50 cm (Turbidity)
Warranty 12 months
Weight Insertion stainless steel: 2.4 kg (5.29 lb.)
What's included? Turbidity/Suspended Solids probe, user manual