跳至产品信息
1 / 1

HACH

HACH LDO sc Model 2 Dissolved Oxygen Sensor, 10 m Cable, Adapter, with SC4500, 2 Channels PN.LXV525.97KTO033&LXV525.CNKTO033

HACH LDO sc Model 2 Dissolved Oxygen Sensor, 10 m Cable, Adapter, with SC4500, 2 Channels PN.LXV525.97KTO033&LXV525.CNKTO033

常规价格 $6,200.46 USD
常规价格 促销价 $6,200.46 USD
促销 售罄

* Please consult before ordering

Accurate process monitoring of dissolved oxygen in water for precise aeration control

Kit including the LDO Model 2 Probe, Mounting Conversion Adapter, and SC4500 Controller (100-240 VAC) with 2 Channels.
For a supremely accurate DO measurements that does not require calibration and is membrane free, turn to an innovator in DO technology, and Hach’s next generation LDO Probe.

Benefits

No Calibration Required

The Hach LDO sc probe uses luminescent dissolved oxygen technology. Traditional DO probes require DO sensor calibration, which increase maintenance requirements.

No Membranes to Replace

There is virtually no maintenance with Hach's breakthrough luminescent technology. There are no membranes to replace, no electrolyte solution to replenish, and no anode or cathode to clean.

No Missed Cleaning Cycles

The Hach LDO sc probe is equipped with Prognosys, a predictive diagnostic system, that allows you to be proactive in your maintenance by alerting you to upcoming instrument issues. Know with confidence whether changes in your dissolved oxygen level measurements are due to changes in your instrument or your water. To make sure routine cleaning cycles are never missed, the probe offers operators customizable diagnostic alert indicators, ensuring the probe can operate at its maximum performance level.
Customizable service indicators trigger a service message so that a cleaning cycle is never missed.

No Drift

Cutting-edge 3D calibration procedure is conducted prior to shipping, the DO probe will not drift and is more accurate than ever before.

No Complications

Our newest DO probe has a robust design with a smaller footprint allows for easier handling with enhanced durability.

Specifications

 

Technical Attributes

Accuracy ± 0.05 ppm Below 5 ppm
Accuracy 2 ± 0.1 ppm Above 5 ppm
Accuracy 3 Temperature: ± 0.2 °C
Body material Stainless steel
Cable Length 10 m (33 ft)
Calibration Method All Probes are factory calibrated and ready to use
Air Calibration: one point, 100% water saturated air
Sample Calibration: comparison to standard instrument, or comparison to Winkler Titration method
Communication Modbus via SC controller
Controller Compatibility SC4500, SC1000, SC200
Diameter 48.25 mm
Flow Rate None required
Interferences No Interferences from the following: H2S, pH, K+, Na+, Mg2+, Ca2+, NH4++, Al3+, Pb2+, Cd2+, Zn2+, Cr (total), Fe2+, Fe3+, Mn2+, Cu2+, Ni2+, Co2+, CN-, NO3-, SO42-, S2-, PO43-, Cl-, anion active surfactants, crude oils, Cl2 < 4 ppm
Measurement Range 2 0 - 20.00 mg/L
Measurement Range 3 0 - 200 %
Options Mounting Adapter & SC4500
Outputs 5x mA Output
Power Requirements (Voltage) 100-240 VAC ±10%, 50/60 Hz; 1 A
Power Supply Without power cord
Range 0 - 20.00 ppm
Repeatability ± 0.1 ppm (mg/L)
Resolution 0.01 ppm (mg/L)
0.1% saturation
Response Time T90 < 40 s
T95 < 60 s
Sensor Immersion Depth Down to 34 m (112 ft.), 345 kPa (50 psi), maximum; accuracy may not be maintained at this depth
Sensor Input #1 Digital
Sensor Input #2 Digital
Software available Non-Claros + Embedded Prognosys
Storage Conditions -20 °C to 70 °C
Transmission Distance 100 m (328 ft.) maximum
Transmission Distance 1000 m (3280 ft.) maximum when used with a termination box
Warranty 36 months
Weight 1 kg (2.2 lbs), probe only
What's included? Hach LDO sc Model 2, DO Probe with Luminescent Dissolved Oxygen Technology (9020000)
SC4500 Controller, Prognosys, 5x mA Output, 2 digital Sensors, 100-240 VAC, without power cord (LXV525.99A11551)
查看完整详细信息