HACH BioTector B3500c Online TOC Analyzer, 0 - 100 mg/L C, 1 stream, 115 V AC PN.B5AFAA152AAC2
HACH BioTector B3500c Online TOC Analyzer, 0 - 100 mg/L C, 1 stream, 115 V AC PN.B5AFAA152AAC2
无法加载取货服务可用情况
* Please consult before ordering
Maximum uptime and reliability for TOC analysis in condensate applications
The Hach BioTector B3500c, with patented Two Stage, Advanced Oxidation Technology, provides accurate results you can be confident in, and gives you maximum reliability and uptime for clean water applications. The analyzer requiries maintenance only twice a year for standard items like reagent replenishment, pump tube replacement and calibration, making it the most affordable TOC analyzer option available.
Because the analyzer body has one of the most compact analyzer footprints available, plants can free up critical wall space that can be used for other instruments. The B3500c requires reagent replenishment only once every six months instead of bi-weekly or monthly, plus the analyzer has the ability to monitor two streams at the same time, eliminating the need for two separate analyzers. The result is accurate, low cost analysis you can rely on.
With maximum reliability and uptime along with the lowest operating costs, the B3500c provides immediate, direct savings and is the industry’s choice when it comes to TOC analysis for condensate applications.
Many additional analyzer versions are available on request.
Direct measurement of Total Organic Carbon, Total Inorganic Carbon, Total Carbon
Chemical Oxygen Demand, Biological Oxygen Demand via correlation
Volatile Organic Carbon via calculation
Benefits
Worry-free TOC
With a patented Two Stage, Advanced Oxidation Technology system, the B3500c provides you with maximum reliability and uptime, without sacrificing accuracy.
Lowest Cost of Ownership
Requiring you to replenish reagents, replace the pump tube, and calibrate only twice a year, the Hach BioTector B3500c has the lowest operating cost available.
Small Footprint = CriticalWall Space Savings
With one of the most compact analyzer footprints, this analyzer frees up wall space for other needed instruments.
Reagent Costs that Don't Kill the Bottom Line
By only needing to replenish reagents every six months, you will see direct bottom line savings in comparison to other systems requiring bi-weekly or monthly replacements.
One Instrument for Multiple Streams
Providing the ability to monitor two streams at the same time, eliminates the double-cost of needing two separate analyzers.
Specifications
Technical Attributes
Ambient Temperature | 5 - 45 °C (41 - 113 °F) |
Communication | Modbus RTU, Modbus TCP/IP & Profibus (when the Profibus option is selected, the digital output signals are sent through the Profibus converter with its specific communication protocol) Except for Zone 1 certification then Modbus RTU, Modbus TCP/IP & Modbus TCP/IP Redundant is available |
Cycle Time | From 5.5 minutes, depending on range and application |
Data Storage | Previous 9999 reaction data |
Display | High contrast 40 character x 16 line backlit LCD with LED backlight |
EExp / Hazardous Location | Certification options are available to European Standards, (ATEX Zone 1, Zone 2), North American Standards (Class I Division 2) and IECEx Zone 1 |
Exceedance Tracking | Full exceedance tracking up to 100 mg/L C |
Humidity | 5 - 85 % (non-condensing) |
Languages | English |
Measurement Method | Infrared Measurement of CO₂ after Oxidation (DIN EN 1484:1997-08, ISO 8245:1999-03, EPA 415.1) |
Multi-Stream | Up to 2 process streams and grab sample |
Number of Channels | 1 Channel / Grab sample-Calibration Port (includes two 4-20mA outputs enabled as standard) |
Number of streams | 1 |
Oxidation Method | Patented Two-Stage Advanced Oxidation Process (TSAO) using Hydroxyl Radicals |
Parameter | Direct measurement of Total Organic Carbon, Total Inorganic Carbon, Total Carbon Chemical Oxygen Demand, Biological Oxygen Demand via correlation Volatile Organic Carbon via calculation |
Particle Size | Up to 100 µm |
Permissible Chloride Range | Up to 30 % w/v |
Power Requirements (Hz) | 60 Hz |
Power Requirements (Voltage) | 115 VAC |
Power Supply | TIC/TOC - 115V |
Protection Class | IP44, standard fan cooled, maximum ambient temperature 45 °C IP54, air cooled, maximum ambient temperature 35 °C IP54, vortex cooled, maximum ambient temperature 50 °C |
Range | 0 - 100 mg/L C |
Range Selection | Automatic or Manual Range Selection |
Repeatability | 0 - 25 mg/L C: ± 3 % of reading or ± 0.03 mg/L, whichever is greater; Lower limit of detection LOD = 0.06 mg/L Exceedance tracking 0 - 100 mg/L C: 5% of reading or 0.5 mg/L C, whichever is greater |
Sample Inlet Temperature | 0 - 60 °C |
Service Interval | 6 month service intervals |
User Interface | Microcontroller with membrane keyboard |
Warranty | 12 months |
Warranty | 1 |
Weight | 46 kg |
What's included? | Includes: B3500c analyser, Tubing, Fuses, Ferrules, Drain, Acid & Base Dip Tubes, C02 Filter & B3500c User Manual |