Smart amperometric Chlorine Dioxide Analyzer: 9187sc

The 9187 sc Chlorine Dioxide (ClO2) Sensor is an online, single-channel industrial sensor that measures ClO2 in drinking water treatment plants, distribution networks, and other applications that require monitoring ClO2 at the ppb and ppm levels. This instrument uses an amperometric method to measure ClO2 concentration. A membrane allows the selective diffusion of ClO2 molecules to the amperometric sensor. The measurement is compensated for temperature.

Benefits

Selective Membrane Avoids Interference from other species

The Hach 9187sc Amperometric Chlorine Dioxide sensor uses a membrane that is selective for chlorine dioxide species. There are no interferences from bromine, chlorine or hydrogen peroxide. The only potential interference is from ozone, which is rarely present in water treated with chlorine dioxide.

Easy Setup and Maintenance

The all-inclusive 9187sc ClO2 system comes preassembled on a panel. The membrane system of the sensor means there are no chemicals used for measurement. Maintenance is minimal and two years of typical maintenance items are included with the system.

Compatible with Hach's "Plug and Play" Digital Controllers

The 9187sc ClO2 sensor is designed to be used with Hach SC digital controllers. Set up is fast and easy, and the system is compatible with the full line of Hach digital sensors.

Specifications

 

Dimensions

Height 10.6 in
Width 6.1 in
 

Technical Attributes

Accuracy 5% or ±10 ppb ClO2, whichever is greater
Calibration Interval 2 months
Calibration Method Zero Calibration: Electrically or with ozone-free water
Calibration: Comparison of lab method with process sample
Enclosure Rating IP66 / NEMA 4X
Flow 14 L/h (200 - 250 mL/min) auto-regulated by flow through cell
Interferences None
Lower Limit of Detection (LOD) 0.01 mg/L ClO2
Maintenance Interval 6 months for membrane and electrolyte (measurement cell)
Measuring Interval Continuous
Measuring Principle Amperometric/Membrane (electrode,
membrane, electrolyte)
Mounting Flat, vertical surface (panel, stand, etc.)
Operating Temperature Range 0 - 45 °C
Parameter Chlorine Dioxide
Pressure Range 0.1 - 2 bar in flow cell
Range 0 - 2 mg/L ClO2
Relative Humidity 0 - 90% non-condensing
Response Time 90% in less than 90 seconds
Sample Input 0.25 " outer diameter
Sample Output 0.5 " inner diameter
Sample Temperature 2 - 45 °C (35.6 - 113 °F)
Standard deviation 1.5
Storage Conditions -20 - 60 °C (-4 - 140 °F)
Temperature Compensation Automatic over sample temperature range
Temperature Compensation Automatic over sample temperature range
Warranty 12 months
Weight 6.5 kg (14.33 lb)
What's included? Hach 9187sc Chlorine Dioxide sensor panel, 4 spare membranes, and Manual.