HACH
HACH 9187sc Chlorine Dioxide Amperometric Sensor PN.LXV434.99.00001
HACH 9187sc Chlorine Dioxide Amperometric Sensor PN.LXV434.99.00001
无法加载取货服务可用情况
* Please consult before ordering
Smart amperometric Chlorine Dioxide Analyzer: 9187sc
The 9187 sc Chlorine Dioxide (ClO2) Sensor is an online, single-channel industrial sensor that measures ClO2 in drinking water treatment plants, distribution networks, and other applications that require monitoring ClO2 at the ppb and ppm levels. This instrument uses an amperometric method to measure ClO2 concentration. A membrane allows the selective diffusion of ClO2 molecules to the amperometric sensor. The measurement is compensated for temperature.
Benefits
Selective Membrane Avoids Interference from other species
The Hach 9187sc Amperometric Chlorine Dioxide sensor uses a membrane that is selective for chlorine dioxide species. There are no interferences from bromine, chlorine or hydrogen peroxide. The only potential interference is from ozone, which is rarely present in water treated with chlorine dioxide.
Easy Setup and Maintenance
The all-inclusive 9187sc ClO2 system comes preassembled on a panel. The membrane system of the sensor means there are no chemicals used for measurement. Maintenance is minimal and two years of typical maintenance items are included with the system.
Compatible with Hach's "Plug and Play" Digital Controllers
The 9187sc ClO2 sensor is designed to be used with Hach SC digital controllers. Set up is fast and easy, and the system is compatible with the full line of Hach digital sensors.
Specifications
Dimensions
Height | 10.6 in |
Width | 6.1 in |
Technical Attributes
Accuracy | 5% or ±10 ppb ClO2, whichever is greater |
Calibration Interval | 2 months |
Calibration Method | Zero Calibration: Electrically or with ozone-free water Calibration: Comparison of lab method with process sample |
Enclosure Rating | IP66 / NEMA 4X |
Flow | 14 L/h (200 - 250 mL/min) auto-regulated by flow through cell |
Interferences | None |
Lower Limit of Detection (LOD) | 0.01 mg/L ClO2 |
Maintenance Interval | 6 months for membrane and electrolyte (measurement cell) |
Measuring Interval | Continuous |
Measuring Principle | Amperometric/Membrane (electrode, membrane, electrolyte) |
Mounting | Flat, vertical surface (panel, stand, etc.) |
Operating Temperature Range | 0 - 45 °C |
Parameter | Chlorine Dioxide |
Pressure Range | 0.1 - 2 bar in flow cell |
Range | 0 - 2 mg/L ClO2 |
Relative Humidity | 0 - 90% non-condensing |
Response Time | 90% in less than 90 seconds |
Sample Input | 0.25 " outer diameter |
Sample Output | 0.5 " inner diameter |
Sample Temperature | 2 - 45 °C (35.6 - 113 °F) |
Standard deviation | 1.5 |
Storage Conditions | -20 - 60 °C (-4 - 140 °F) |
Temperature Compensation | Automatic over sample temperature range |
Temperature Compensation | Automatic over sample temperature range |
Warranty | 12 months |
Weight | 6.5 kg (14.33 lb) |
What's included? | Hach 9187sc Chlorine Dioxide sensor panel, 4 spare membranes, and Manual. |