HACH 5500sc Phosphate High Range Analyzer, 1 Channel, Reagents Included PN.5500.KTO.PH.A1U
HACH 5500sc Phosphate High Range Analyzer, 1 Channel, Reagents Included PN.5500.KTO.PH.A1U
无法加载取货服务可用情况
* Please consult before ordering
Lower Maintenance, Less Downtime
The 5500sc Phosphate Analyzer needs only two liters of reagent to perform unattended for up to 90 days; twice as long as the Series 5000. The industry's only pressurized reagent delivery system eliminates the frequent maintenance associated with pumps. Prognosys which is a predictive diagnostic system, allows you to be proactive in your maintenance. Warning LEDs, and high-visibility notification screens let you avoid unplanned downtime. No more dripping reagents on the instrument, the floor, or your clothing while fumbling with tubes and straws. Simply match the color-coded cap to the sealed reagent bottle and twist gently. Grab Sample In and Grab Sample Out features allow quick analysis of a grab sample poured into the analyzer, and facilitate taking a sample out of the online silica analyzer to verify in a lab test.
Benefits
90 Days of Continuous Run Time
Two liters of reagent are required for the silica analyzer to perform unattended for up to 90 days; twice as long as the Series 5000.
Save Time on Maintenance
The industry's only pressurized reagent delivery system eliminates the frequent maintenance associated with pumps.
Avoid Downtime
Prognosys, the predictive diagnostic system, allows you to be proactive in your maintenance. Warning LEDs, and high-visibility notification screens let you avoid unplanned downtime.
Clean, Fast and Easy Reagent Change
No more dripping reagents on the instrument, the floor, or your clothing while fumbling with tubes and straws. Simply match the color-coded cap to the sealed reagent bottle and twist gently.
Verify Easily with Hach Lab Products so you don't Waste Time Second-guessing
Grab Sample In and Grab Sample Out features allow quick analysis of a grab sample poured into the analyzer, and facilitate taking a sample out of the analyzer to verify in a lab test.
Specifications
Technical Attributes
Accuracy | LR model: ±4 µg/L or ±4% of reading, whichever is greater; HR model: ±500 µg/L or ±5% of reading, whichever is greater |
Alarm | Four relays output; type: not powered SPDT relays, each rated at 5 A resistive, 240 VAC maximum Connection: 18 to 14 AWG wire, 18 AWG stranded recommended |
Application | Pure water / Power |
Certifications | CE (EN 61326-1: 2006; EN 61010-1: 2010; EN 60529: 1991, +A1:2000 ) KC (EN 61326-1: 2006) C-tick (EN 61326-1: 2006) cETLus (UL 61010-1: 2012; NEMA 250: 2003; CSA C22.2 No 61010-1: 2012) |
Controller Compatibility | SC200, SC1000 |
Enclosure Rating | IP56 / NEMA 4X |
Fitting Type | Sample line and sample bypass drain: 6 mm (¼-in.) Air purge inlet: 6 mm (¼-in.) Chemical and case drains: 9.5 mm (3/8-in.) |
Grab Sample | Grab Sample In and Grab Sample Out capability |
Light Source | Class 1M LED (light emitting diode) with a peak wavelength of 810 nm |
Lower Limit of Detection (LOD) | LR model: 4 µg/L HR model: 200 µg/L |
Manual Languages | English French Spanish B. Portuguese Chinese Japanese Korean Thai German Italian C. Portuguese Czech Danish Dutch Polish Swedish Finnish Bulgarian Hungarian Romanian Lithuanian Russian Turkish Slovak Slovenian Croatian Greek Estonian |
Measuring Principle | Colorimetric |
Mounting | Wall, panel or table |
Number of Channels | 1 |
Operating Humidity | 5 - 95 % non-condensing (indoor use only) |
Operating Temperature Range | 5 - 45 °C |
Outputs | 4 - 20 mA |
Parameter | High Range Phosphate |
Pollution Degree | 2/II |
Power Requirements (Hz) | 50/60 Hz |
Power Requirements (Voltage) | 100 - 240 VAC |
Protection Class | I |
Range | 200 - 50000 µg/L as PO₄ |
Reagent Consumption | 2 L of each reagent every 90 days with 15 minute cycle time |
Relays | Four; type: not powered SPDT relays, each rated at 5 A resistive, 240 VAC maximum |
Repeatability | LR model: ±1% HR model: ±500 µg/L or ±5% of reading, whichever is greater |
Response Time | Typically, 9.5 minutes at 25 °C (77 °F); changes with temperature |
Sample Flow Rate | 55 - 300 mL/min |
Sample Pressure | 2 - 87 psi (to Preset Pressure Regulator) |
Sample Temperature | 5 - 50°C (41 - 122°F) |
Storage Conditions | -20 - 60 °C |
Warranty | 12 months |
Weight | 20 kg (45 lb) without reagents and standards, 36.3 kg (80 lb) with reagents |
What's included? | List of content: 5500sc analyzer, reagents set for up to 90 days of use, installation kit, Hach user manuals |