HACH
HACH 5500sc Ammonia Monochloramine Analyzer, 2 Channel PN.5500.AMC.2-CN
HACH 5500sc Ammonia Monochloramine Analyzer, 2 Channel PN.5500.AMC.2-CN
无法加载取货服务可用情况
* Please consult before ordering
Chloramination made easy.
The 5500sc Ammonia Monochloramine Analyzer provides all the information you need to eliminate nitrification events and taste and odor issues, giving you total confidence in your process.
Benefits
Easy operation
The analyzer offers an easy-to-operate, low-maintenance solution to help you maintain the proper chlorine to ammonia ratio and assure there is no free ammonia in your system that could lead to nitrification. We removed the traditional pumps associated with reagent delivery and replaced them with a pressurized system to eliminate the hassles and maintenance that pumps can cause.
Reliability without all the work
With Prognosys, the analyzer’s onboard predictive diagnostic software, you will have early insight into the measurement reliability and service requirements of your instruments. A user-friendly interface, color coded reagent bottles and at-a-glance status lights will offer peace of mind the instrument is up and running.
Improved control of your chloramination process
The 5500sc Ammonia Monochloramine Analyzer provides continuous monitoring, so you can trust that your instrument is giving you the information you need to control your chloramination process.
Specifications
Technical Attributes
Accuracy | ± 5 % or 0.01 ppm (as N) for sample temperature 5 - 40 °C (41 - 104 °F); ±10% or 0.02 ppm for sample temperature 40 - 50 °C (104 - 122 °F), whichever is greater |
Alarm | Four; not powered SPDT relays, each rated at 5A resistive, 240 VAC maximum |
Certifications | CE (EN 61326-1: 2006; EN 61010-1: 2010; EN 60529: 1991, +A1:2000 cETLus (UL 61010-1:2012; NEMA 250:2003; CSA C22.2 No 61010-1:2012) Australian RCM Marking |
Communication | Modbus RS485, Profibus DP (available with external controller), 4-20mA Output |
Cycle Time | 4.5 min |
Enclosure Rating | IP56 / NEMA 4X |
External Filter | No |
Grab Sample | Grab Sample In and Grab Sample Out capability |
Inlet | 6mm OD push-to-connect fitting for plastic tubing |
Light Source | Class 1M LED (light emitting diode) with a peak wavelength of 650 nm |
Lower Limit of Detection (LOD) | 0.01 ppm (as N) |
Material | Polycarbonate (PC)/ABS case, PC Door, PC hinges and latches, 316 Stainless Steel hardware |
Measuring Interval | 4.5 minutes |
Mounting | Wall, panel, or table |
Number of Channels | 2 |
Number of sample streams | 1 or 2 in programmable sequence |
Operating Humidity | 5 - 95 % non-condensing |
Operating Temperature Range | 5 - 45 °C (41 - 113 °F) |
Options | Standard |
Outlet | 11mm (7/16 in.) ID slip-on fitting |
Outputs | Four 0/4-20 mA Outputs, load impedance 600 ohm maximum |
Parameter | Total Ammonia, Monochloramine, and Free Ammonia |
Pollution Degree | 2/II |
Power Requirements (Hz) | 50 - 60 Hz |
Power Requirements (Voltage) | 100 - 240 VAC |
Range | 0.01 - 2 ppm (as N), 0.1 - 10.0 mg/L (as Cl₂) |
Reagent Consumption | 1L of reagents every month with 5 minute cycle time |
Repeatability | 3 % or 0.01 ppm (as N), whichever is greater |
Response Time | Within 5 minutes |
Sample Flow Rate | 100 - 1000 mL/min |
Sample Pressure | 2.5 - 87 psi (0.17 - 6.8 bar) |
Sample Temperature | 5 - 50 °C (41 - 122 °F) |
Storage Conditions | -20 - 60 °C (-4 - 140 °F) |
Warranty | 12 months |
Weight | 20.5 kg (45.19 lb) without reagents and standards, 30 kg (66.14 lb) with reagents, standards and cleaning solution |
What's included? | 5500sc Ammonia Monchloramine Analyzer, 2 Channel with installation kit and user manuals, reagents and standards for one month use |