Dendi Density meter
Display resolution: 0.0001g /cm³ (0.1kg /m³), temperature range: +15° C to +30° C, temperature accuracy: ±0.01° C
Portable Density/Specific Gravity/Concentration Meter 2 YEARS WARRANTY
Principle of operation
The operating principle of the device is – weighting of the glass float with filler fully immersed in liquid. It allows measuring observed density and temperature of wide range of opaque and transparent liquids. The buoyancy force of liquid acts on the float, which has precise weight and volume; the float's movement is transmitted to the beam with balance. The electronics employ sophisticated signal processing and computational algorithms to deliver high accuracy measurements. The device has a rugged design with little need for service and easy cleaning. The calibration requires only distilled water. Built-in tables of water densities at testing temperatures and air density (average value for standard european conditions) allows to determine linear dependence of density and weight (see graph on top). Taken together these features result in a device with a long service life and very low cost of ownership.
> Wide range of supported measuring units
> Covered Density range: 500...2 000 kg/m³
> Automatic measurements
> Simple in operation, safe
> Density/Concentration and Temperature measurements in one instrument
> Unit conversion
> Automatic temperature compensation
> No experienced personnel required
Preparation of the Samples
> Liquids for measurements must be gas-free and their temperature must be equal to the ambient temperature ±5℃ .
> If the same beaker is used for various liquids clean it thoroughly and dry before filling with new sample!
> For accurate sample preparation place the float into the beaker and fill it with measured liquid up to the top.
> Place the beaker to the special tray on the base of the device and set the float on the measuring arm - to ensure that the level sample is 2-4 mm above the float.
> Then you may take the float off the beaker and make a mark on the beaker with the help of marker for glass.
Preparation of the Device
> Make an external survey of the float and other submersible parts. They must be clean and dry, without mechanical injuries. Any dents or impurity adhered on the float will influence the accuracy of the density measurements!
> In case of impurity – wash the float in appropriate solvent and dry it with some non-fluffy material (paper towel, rags, etc.).
> Set and remove the float on the measuring arm – to check its free running. All the time take care of cleanness in the inlet of the measuring arm!
> Set the device on the workplace and adjust its horizontal position (in accordance with level vial) with the help of adjusting screws.
> Switch ON the device and warm it up for 10 minutes.
Specifications
|
Model |
DenDi-1 |
DenDi-2 |
|
Density |
0… 3 g/cm³ (0… 3000 kg/m³) |
0 to 3 g/cm³ (0 to 3000kg/m³) |
|
Measurement accuracy |
±0.001 g/cm³ (±1.0 kg/m³) |
±0.0005 g/cm³ (±0.5 kg/m³) |
|
Repeatability |
±0.0005 g/cm³ ( ±0.5 kg/m³) |
±0.00025 g/cm³ (±0.25 kg/m³) |
|
Display resolution |
0.0001 g/cm³ (0.1 kg/m³) |
0.0001 g/cm³ (0.1 kg/m³) |
|
Temperature |
+15℃ to +30℃ |
+15℃ to +30℃ |
|
Temperature accuracy |
±0.01℃ |
±0.01℃ |
|
Quantity of samples required |
100mL |
100mL |
|
Display unit |
Relative density :g/cm³, kg/m³, lb/gal, lb/ft³; API; SG Base density 15℃, 20℃, 60O F; API60; SG60 ASTM D1250 Table Albuminance 0Bx, alcohol concentration vol%, beer maltiness 0P Temperature ℃ and O F |
Relative density :g/cm³, kg/m³, lb/gal, lb/ft³; API; SG Base density 15℃, 20℃, 60O F; API60; SG60 ASTM D1250 Table Albuminance 0Bx, alcohol concentration vol%, beer maltiness 0P Temperature ℃ and O F |
|
Viscosity compensation |
automatic |
automatic |
|
Temperature compensation |
automatic |
automatic |
|
Display |
LCD display, background lighting |
|
|
Data storage |
By date, time can store up to 998 groups of data |
|
|
Communication |
Through the infrared interface and printer, PC connection |
|
|
Software |
Windows software is optional |
|
|
Ddimension(H x L x W) |
135*100*190mm |
135*100*190mm |
|
Weight |
1.3kg |
1.3kg |
|
Battery |
NiMH 9V 150mAh |
NiMH 9V 150mAh |
|
Data storage |
The machine can store 998 measurement data |
|