{"product_id":"mettler-toledo-chloride-ion-selective-electrode-dx235-cl-chlorid-mettler-toledo-51340400","title":"Mettler Toledo Chloride ion selective electrode DX235-Cl Chlorid Mettler Toledo 51340400","description":"\u003cp\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e\u003cstrong\u003e* Please contact us for the best quote.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eChloride ion selective electrode DX235-Cl Chlorid\u003cbr\u003eIon-selective half-cell\u003c\/p\u003e\n\u003cdiv class=\"productmodel__accordion__title accordionLight__header accordionLight__header--arrowLeft\"\u003e\n\u003cdiv class=\"accordionLight__header__text\"\u003e\n\u003ch3\u003e\u003cspan dir=\"auto\"\u003eSpecification\u003c\/span\u003e\u003c\/h3\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"productmodel__accordion__content accordionLight__content displayed\" aria-controlledby=\"accordion-0\"\u003e\n\u003csection class=\"productmodel__specifications__top\"\u003e\n\u003cdiv class=\"specificationspm productspecifications\"\u003e\n\u003carticle class=\"productSpecifications\"\u003e\n\u003ch3\u003e\u003cspan dir=\"auto\"\u003eSpecifications - Chloride ion selective electrode DX235-Cl Chlorid\u003c\/span\u003e\u003c\/h3\u003e\n\u003ctable class=\"productSpecifications__table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan dir=\"auto\"\u003eMeasurement range\u003c\/span\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cspan dir=\"auto\"\u003e2*10-5 – 1 mol\/L\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan dir=\"auto\"\u003eTemperature range\u003c\/span\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cspan dir=\"auto\"\u003e0 °C – 80 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan dir=\"auto\"\u003eOptimal pH range\u003c\/span\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cspan dir=\"auto\"\u003e2 – 13\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan dir=\"auto\"\u003econnector\u003c\/span\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cspan dir=\"auto\"\u003eS7\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan dir=\"auto\"\u003eLiquid network type\u003c\/span\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cspan dir=\"auto\"\u003e--\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan dir=\"auto\"\u003eElectrode rod material\u003c\/span\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cspan dir=\"auto\"\u003ePOM\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan dir=\"auto\"\u003eElectrode type\u003c\/span\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cspan dir=\"auto\"\u003ehalf battery\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan dir=\"auto\"\u003eElectrode rod length\u003c\/span\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cspan dir=\"auto\"\u003e120 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan dir=\"auto\"\u003eElectrode rod diameter\u003c\/span\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cspan dir=\"auto\"\u003e12 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan dir=\"auto\"\u003eparameter\u003c\/span\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cspan dir=\"auto\"\u003eISE\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan dir=\"auto\"\u003eReference electrolyte\u003c\/span\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cspan dir=\"auto\"\u003e1 mol\/L KNO3\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan dir=\"auto\"\u003eMembrane type\u003c\/span\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cspan dir=\"auto\"\u003esolid state\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan dir=\"auto\"\u003eIntelligent Electrode Management (ISM®)\u003c\/span\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cspan dir=\"auto\"\u003eno\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan dir=\"auto\"\u003eTemperature probe\u003c\/span\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cspan dir=\"auto\"\u003eno\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan dir=\"auto\"\u003esignal type\u003c\/span\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cspan dir=\"auto\"\u003esimulation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan dir=\"auto\"\u003eion\u003c\/span\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cspan dir=\"auto\"\u003eethylene\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan dir=\"auto\"\u003eReference electrolyte order number\u003c\/span\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cspan dir=\"auto\"\u003e51343182\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan dir=\"auto\"\u003eISA solution\u003c\/span\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cspan dir=\"auto\"\u003e1 mol\/L KNO3\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan dir=\"auto\"\u003eMembrane kit\u003c\/span\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cspan dir=\"auto\"\u003e51340007\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan dir=\"auto\"\u003eMeasurement type\u003c\/span\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cspan dir=\"auto\"\u003eDirect measurement (ion selection method)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan dir=\"auto\"\u003eIncludes cable\u003c\/span\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cspan dir=\"auto\"\u003eno\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan dir=\"auto\"\u003eInstrument connector\u003c\/span\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cspan dir=\"auto\"\u003eFlexibility (detachable cable)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan dir=\"auto\"\u003eConnector on the electrode\u003c\/span\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cspan dir=\"auto\"\u003eS7\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan dir=\"auto\"\u003eElectrode type\u003c\/span\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cspan dir=\"auto\"\u003eIon Selective Sensor (ISE)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan dir=\"auto\"\u003eApplicable titrator types\u003c\/span\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan dir=\"auto\"\u003eCompact potentiometric titrator,\u003c\/span\u003e\u003cbr\u003e\u003cspan dir=\"auto\"\u003eBeyond series titrator\u003c\/span\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan dir=\"auto\"\u003eIon type\u003c\/span\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cspan dir=\"auto\"\u003eAnion\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan dir=\"auto\"\u003eProduct Line\u003c\/span\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan dir=\"auto\"\u003eCompact potentiometric titrator,\u003c\/span\u003e\u003cbr\u003e\u003cspan dir=\"auto\"\u003eBeyond series titrator\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/article\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e","brand":"Mettler Toledo","offers":[{"title":"Default Title","offer_id":47829432565982,"sku":null,"price":2488.71,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/0636\/3870\/files\/1_857514d7-2a55-4c50-900c-a49edb94bc27.jpg?v=1768444638","url":"https:\/\/www.ltprocess.com\/products\/mettler-toledo-chloride-ion-selective-electrode-dx235-cl-chlorid-mettler-toledo-51340400","provider":"Instrument Trading Center","version":"1.0","type":"link"}