{"product_id":"m5000-melting-point-meter-for-automatic-measurements","title":"M5000 Melting point meter for automatic measurements","description":"\u003ch3\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e*Please Contact Us for the Best Quote and to Confirm Delivery Time\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch3\u003eMelting point meter for automatic measurements\u003c\/h3\u003e\n\u003cp\u003eMEASUREMENT RANGE：25–400 °C； MEASUREMENT ACCURACY：±0.3 °C (25–200 °C)；±0.5 °C (200–400 °C)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eFully automatic measurements\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe M5000 provides fast, easy and automatic examination of powdery substances with a melting point up to 400 °C. Due to the automatic determination of the melting point, an objective measurement result is always guaranteed. The high preheating rate and the integrated fan cooling allow fast and reliable measurements in any temperature range. The display provides a well-arranged readout of all important measuring data.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e* Fully automatic measurement\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e*\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003e1 capillary intake\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e*\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003eLCD display\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e*\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003eAlarm signal when reaching the melting point\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e*\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003eFast cooling through integrated fan\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e*\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003eDigital display of all important data\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e*\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003eDisplay in German or English\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e*\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003eWith RS-232 interface for printer CBM910\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e*\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003eEasy-to-clean membrane keypad\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eI\u003c\/span\u003e*\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003encludes protective cover and 100 capillaries\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e*\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003eSmall sample volume\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eTypical applications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe determination of the melting point is of great importance in the identity test, since many substances can be determined by their melting point.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe purity of substances can also be qualitatively measured via melting point. A well-defined melting point is only given for 100 percent pure substances. Due to impurities, such as impurities or dopants, most substances have a melting interval (beginning of the melt to completion of the melt) of a few degrees Celsius. Even impurities during the manufacture of chemicals cause this melting point to expand to a melting interval. As a result, most substances that are examined with a melting point meter have a melting interval. This effect is used to identify the degree of impurity of the substance.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eModel specifications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable border=\"1\" cellspacing=\"0\" class=\"MsoTableGrid\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e Parameter\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eM5000\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eMEASUREMENT RANGE\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e25–400 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eMEASUREMENT ACCURACY\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e±0.3 °C (25–200 °C)\u003cbr\u003e±0.5 °C (200–400 °C)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eRESOLUTION\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e0.1 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003ePREHEATING RATE\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eTo 200 °C approx. 4.0 min\u003cbr\u003eTo 300 °C approx. 9.0 min\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eHEATING RATE\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e1 °C min-1\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eNO. OF CAPILLARIES\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e1\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eCAPILLARY Ø\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e1.4 mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eINTERFACE\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eRS-232\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eIP CODE\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eIP20\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003ePOWER SUPPLY\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e90–264 V\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eDIMENSIONS (W X H X D)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e220 mm x 150 mm x 340 mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eWEIGHT\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e4.1 kg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"ChemTron","offers":[{"title":"Default Title","offer_id":48153391169758,"sku":null,"price":99999.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/0636\/3870\/files\/1_2ac45b9f-92b4-44ec-9291-be08179b81e0.jpg?v=1776999325","url":"https:\/\/www.ltprocess.com\/products\/m5000-melting-point-meter-for-automatic-measurements","provider":"Instrument Trading Center","version":"1.0","type":"link"}