{"product_id":"m3000-melting-point-meter-for-semi-automatic-measurements","title":"M3000 Melting point meter for semi-automatic measurements","description":"\u003ch3\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e*Please Contact Us for the Best Quote and to Confirm Delivery Time\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch3\u003eMelting point meter for semi-automatic measurements\u003c\/h3\u003e\n\u003cp\u003eMEASUREMENT RANGE:30–360 °C； MEASUREMENT ACCURACY:±0.3 °C (30–200 °C)；±0.5 °C (200–360 °C)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eSemi-automatic measurement using 10x observation optics\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe M3000 provides fast and easy examination of powdery substances with a melting point up to 360 °C. Due to the triple capillary intake, it is possible to analyse three samples within one measurement run. Thanks to the preheating rate and the integrated fan cooling, fast measurements are possible in any temperature range. The display provides a wellarranged readout of all important measuring data.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e* Semi-automatic measurement\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e* 3 capillary intakes\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e* LCD-Display\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e* Monitoring of the illuminated sample via lens\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e* Fast cooling through integrated fan\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e* Digital display of all important data\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e* Display in German or English\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e* With RS-232 interface for printer CBM910\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e* Easy-to-clean membrane keypad\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eI* ncludes protective cover and 100 capillaries\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e* Small sample volume\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eTypical applications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe determination of the melting point is of great importance in the identity test, since many substances can be determined by their melting point.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe purity of substances can also be qualitatively measured via melting point. A well-defined melting point is only given for 100 percent pure substances. Due to impurities, such as impurities or dopants, most substances have a melting interval (beginning of the melt to completion of the melt) of a few degrees Celsius. Even impurities during the manufacture of chemicals cause this melting point to expand to a melting interval. As a result, most substances that are examined with a melting point meter have a melting interval. This effect is used to identify the degree of impurity of the substance.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eModel specifications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable border=\"1\" cellspacing=\"0\" class=\"MsoTableGrid\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e Parameter\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eM3000\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eMEASUREMENT RANGE\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e30–360 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eMEASUREMENT ACCURACY\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e±0.3 °C (30–200 °C)\u003cbr\u003e±0.5 °C (200–360 °C)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eRESOLUTION\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e0.1 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003ePREHEATING RATE\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eTo 200 °C approx. 4.0 min\u003cbr\u003eTo 300 °C approx. 8.0 min\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eHEATING RATE\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e1 °C min-1\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eOBSERVATION LENS\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e10x\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eNO. OF CAPILLARIES\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e3\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eCAPILLARY Ø\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e1.4 mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eINTERFACE\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eRS-232\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eIP CODE\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eIP20\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003ePOWER SUPPLY\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e90–264 V\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eDIMENSIONS (W X H X D)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e210 mm x 360 mm x 230 mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eWEIGHT\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e4.3 kg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"ChemTron","offers":[{"title":"Default Title","offer_id":48153373868254,"sku":null,"price":99999.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/0636\/3870\/files\/1_5ff0ab2b-de1b-4db3-a45c-a815c154f34b.jpg?v=1776999180","url":"https:\/\/www.ltprocess.com\/products\/m3000-melting-point-meter-for-semi-automatic-measurements","provider":"Instrument Trading Center","version":"1.0","type":"link"}