{"product_id":"kruss-p8000-p-p8100-p-polarimeters-with-peltier-temperature-control","title":"KRUSS P8000-P \/ P8100-P Polarimeters with Peltier temperature control","description":"\u003ch3\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e*Please Contact Us for the Best Quote and to Confirm Delivery Time\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch3\u003ePolarimeters with Peltier temperature control\u003c\/h3\u003e\n\u003cp\u003eMEASUREMENT RANGE：±90°±259 °Z\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePrecise temperature control using Peltier technology\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eHigh-precision measurements through temperature control without an additional device – this is what our polarimeter models P8000-P and P8100-P offer, which otherwise have the same functional scope and the same characteristics as the other devices of the P8000 series. They are recommended if the temperature of the sample is to be controlled extremely accurately within a very short period of time and with a short control cycle and independent of the outside temperature.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e* Temperature measurement directly inside the sample\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e* Accurate, homogenous, fast Peltier temperature control\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e* Chemical-resistant, unbreakable measurement tube\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e* Highest accuracy over the entire measurement range\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e* Very short measurement time of approx. 1 s\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e* Measurement up to an optical density of 3.0 OD\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e* Intuitive operation via touch-screen display\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e* Predefined scales (opt. rotation, spec. rotation, int. sugar scale, concentration)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e* Any number of freely definable scales with conversions based on tables or formulas\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e* Chemical-resistant materials\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e* Compliance with GMP\/GLP, 21 CFR Part 11, Pharmakopöen (USP, BP, JP, Ph. Eur.), FDA, ISO, HACCP, OIML, ASTM, ICUMSA, NIST\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eTypical applications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe P8000-P polarimeters can be used for a variety of applications in the pharmaceutical, chemical, sugar, food and beverage industry, as well as for the production of flavors and fragrances.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e* Determination of the concentration of sugar as an ingredient of pharmaceutical agents\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e* Purity control and content determination\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e* Determination of the stereochemical composition and mutarotation\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e* Characterisation of new synthetic substances\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e* Purity control and concentration determination\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e* Monitoring of chemical processes during the production of optically active substances\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e* Characterisation tests in research laboratories\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e* Reaction kinetic analyses\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel specifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable border=\"1\" cellspacing=\"0\" class=\"MsoTableGrid\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eP8000-P\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eP8100-P\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\n\u003cp\u003e\u003cspan\u003eMEASUREMENT DATA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eSCALES\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e\u003cspan\u003eOptical rotation [°]\u003cbr\u003eInt. sugar scale [°Z]\u003cbr\u003eConcentration [g\/100 ml]\u003cbr\u003eSpec. rotation\u003cbr\u003eUser-defined\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eMEASUREMENT RANGE\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e\u003cspan\u003e±90°\u003cbr\u003e±259 °Z\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eMEASUREMENT ACCURACY\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e±0.003°\u003cbr\u003e±0.01 °Z\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e±0.002°\u003cbr\u003e±0.01 °Z\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eRESOLUTION\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e\u003cspan\u003e0.001°\u003cbr\u003e0.01 °Z\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eMEASUREMENT PERIOD ±90°\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e\u003cspan\u003eApprox. 1 s\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eLIGHT SOURCE\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e\u003cspan\u003e1 LED with filter\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eWAVELENGTH\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e\u003cspan\u003e589 nm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\n\u003cp\u003e\u003cspan\u003eTEMPERATURE DATA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eTEMPERATURE CONTROL\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e\u003cspan\u003eWith measurement tube PRG-100-EPT with 3 integrated Peltier elements\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eTEMPERATURE CONTROL RANGE\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e\u003cspan\u003e15–40 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eTEMPERATURE CONTROL ACCURACY\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e\u003cspan\u003e±0.2 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eTEMPERATURE MEASUREMENT\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e\u003cspan\u003eWith measurement tube PRG-100-EPT\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eTEMPERATURE MEASUREMENT RANGE\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e\u003cspan\u003e0–99.9 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eTEMPERATURE MEASUREMENT RESOLUTION\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e\u003cspan\u003e0.1 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eTEMPERATURE MEASUREMENT ACCURACY\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e\u003cspan\u003e±0.1 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"ChemTron","offers":[{"title":"Default Title","offer_id":48152911479006,"sku":null,"price":99999.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/0636\/3870\/files\/1_136c12b5-6d37-4c28-b6d6-9de749835c9b.jpg?v=1776998543","url":"https:\/\/www.ltprocess.com\/products\/kruss-p8000-p-p8100-p-polarimeters-with-peltier-temperature-control","provider":"Instrument Trading Center","version":"1.0","type":"link"}