{"product_id":"chemtron-viscoclock-automatic-viscometer","title":"ChemTron ViscoClock Automatic Viscometer","description":"\u003cdiv class=\"memol-title clearfix\"\u003e\n\u003ch3 class=\"fl\"\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003ePlease Contact Us for the Best Quote and to Confirm Delivery Time\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch3 class=\"fl\"\u003eDescription\u003ci class=\"fa fa-qq\" aria-hidden=\"true\"\u003e\u003c\/i\u003e\n\u003c\/h3\u003e\n\u003cdiv class=\"social-nav\"\u003e\n\u003ci class=\"fa fa-weibo\" aria-hidden=\"true\"\u003e\u003c\/i\u003e\u003ci class=\"fa fa-weixin\" aria-hidden=\"true\"\u003e\u003c\/i\u003e\u003ca class=\"linkedin\"\u003e\u003c\/a\u003e\u003cstrong\u003e\u003cspan\u003eAutomatic Viscometer\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cspan\u003eViscoClock is an automatic timing device specially used for measuring viscosity and relative viscosity by glass capillary method. It is easy to operate and can store data. It is a good helper in viscosity measurement experiments!\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eViscoClock is equipped with an infrared detection device, which can accurately measure the time when the sample (quantitative constant temperature) flows through the glass capillary viscosity tube, so that visual observation and manual stopwatch timing have become a thing of the past. When measuring, first install the glass capillary viscosity tube on the ViscoClock, and then put it into the JULABO transparent viscosity bath to keep the temperature constant. After the temperature is constant, use a manual pump (pressure pump or suction pump) to lift the sample in the viscosity tube to the buffer bulb. Then after pressing the measurement switch, the measurement and timing are automatically completed. The bright display shows sample flow time, date, time, sample ID and viscotube ID.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eAutomatic measurement of sample transit time\u003c\/strong\u003e - ViscoClock is available with SIA Ubbelohde tubes, micro Ubbelohde tubes and micro Oswald tubes. The upper and lower sets of infrared liquid level detection devices can accurately complete the timing task. Compared with naked eye observation and manual stopwatch timing, ViscoClock automatic time measurement has high repeatability. Therefore, some viscosity measurement standards also allow the use of automatic viscosity measurement systems, which can shorten the flow time, save experiment time and improve work efficiency\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePerformance and material\u003c\/strong\u003e - ViscoClock can be used in the viscosity measurement environment of -40...+150 ℃, its bracket is made of high-quality PPA polymer, allowing the medium in the JULABO constant temperature bath: water, alcohol, ethylene glycol , paraffin oil, silicone oil, etc. The shell material of the electronic part is PP\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSimple operation\u003c\/strong\u003e - when using Ubbelohde's viscosity tube to measure, the on-off of the emptying tube is controlled by a solenoid valve, and the sealing effect will be better compared with the previous mechanical seal.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eData storage and transmission\u003c\/strong\u003e - measurement results can be stored in USB flash memory, information including: date, time, sample ID, viscosity tube ID. Can be saved as PDF (non-editable) and csv (editable). In addition, it can also be directly connected to a printer (TZ 3863) and a computer.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSample and Viscosity Tube Name Editing\u003c\/strong\u003e —Users can enter two digits as the sample and viscosity tube name numbers, and this information will be stored in the report together with the measurement date, time, and flow time.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eJ pair viscosity application\u003c\/strong\u003e - in order to ensure accurate J pair viscosity measurement accuracy, it is recommended to use standard samples to calibrate the entire measurement system before measurement. The constants of automatic calibration can be slightly different from manual calibration constants, which can ensure the elimination of system errors.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eRelative Viscosity Applications\u003c\/strong\u003e - When measuring the relative viscosity of a sample, an uncalibrated viscosity tube can be selected, as the calibration constants will not be involved in the later calculations in this case.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eClear Viscosity Baths\u003c\/strong\u003e - ViscoClock can be used with clear viscosity baths such as JULABO brand DT-31A, DT-16G and DT-18V\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable border=\"1\" cellspacing=\"0\" class=\"GridTableLight\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e\u003cspan\u003eTechnical Parameters\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eMeasurement time range\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eZ length up to 999.99s, resolution 0.01s\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eTime Measurement Accuracy\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e±0.01s\/±1 digit; but the accuracy is not more than 0.1%\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eViscosity measurement range\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e0.35-10000mm2\/s(cSt)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003edisplay screen\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eLCD display, 128*64 pixels, 51×31mm (w×h)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eData interface\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eUSB host can be connected to U disk or printer TZ 3863, USB OTG can be connected to PC or printer TZ 3863\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e515×90×30mm (H×W×D)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eweight\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e450g (weight without viscosity tube installed)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCE certification\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eVoltage complies with 2014\/35\/EU\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eComplies with EN 61 010-1:2011-07, EMC Directive 2014\/30\/EU\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eTested to EN 61 326 Part1:2012, EN 50 581:2013-02\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eCompliant with RoHS Regulation 2011\/65\/EU\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eFCC certification\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eApplicable viscometer type\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eSIA Ubbelohde Viscometer (DIN, ISO, ASTM, Micro), SIA Micro Oswald Viscometer\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eApplicable viscosity bath\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eJULABO brand viscosity baths\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"ChemTron","offers":[{"title":"Default Title","offer_id":48072265531614,"sku":null,"price":99999.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/0636\/3870\/files\/1_7b973f2a-c404-4fb7-93c4-316b67408ecf.jpg?v=1775717411","url":"https:\/\/www.ltprocess.com\/products\/chemtron-viscoclock-automatic-viscometer","provider":"Instrument Trading Center","version":"1.0","type":"link"}