{"product_id":"chemtron-visco-370-automatic-kinematic-viscosity-measurement-system","title":"ChemTron VISCO 370 Automatic Kinematic Viscosity Measurement System","description":"\u003ch3\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003ePlease Contact Us for the Best Quote and to Confirm Delivery Time\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch3\u003eVISCO 370 Automatic Kinematic Viscosity Measurement System\u003c\/h3\u003e\n\u003cp\u003ePressure method: 0.35-1800mm2\/s (cSt), vacuum method: 0.35-5000mm2\/s (cSt) Time measurement range: up to 9999.99s, resolution 0.01s\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u0026gt; Powerful fully automatic viscosity testing system for almost all viscosity measurement applications. The instrument conforms to the ASTMD445 standard and provides high-precision temperature control and time measurement\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u0026gt; The supporting software helps customers complete the test with powerful functions, and is a powerful tool for a large number of viscosity measurements in the laboratory\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u0026gt; Applicable viscosity tubes: Ubbelohde viscometer, Cannon-Fenske viscometer, micro Ubbelohde viscometer, micro Oswald viscometer, and thermal conductivity viscometer, etc.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u0026gt; Each viscometer is ISO\/ASTM calibrated with its own metrology certificate, viscometer constants to four decimal places\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u0026gt; With modular design, it can be easily expanded to 8 measuring units (viscosity measurement of 8 viscosity tubes at the same time), each measuring unit can use different measuring principles to measure different fluids\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u0026gt; PC-controlled multi-position automatic cleaning system, which can clean each viscosity tube simultaneously or separately, single-solvent or double-solvent cleaning is optional\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u0026gt; Equipped with viscosity testing software as standard to realize remote control. This software can directly complete polymer molecular weight calculation, oil K value calculation, absolute and relative viscosity measurement, Saybolt viscosity measurement. And can record all the viscosity experiment data\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u0026gt; All parts that may be in contact with the sample are made of anti-chemical corrosion materials, safe and convenient to use\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u0026gt; Integrate vacuum method and pressure method, suitable for viscosity measurement of any sample Pressure method: 0.35~1800 mm2\/ s; Vacuum method: 0.35~5000 mm2\/ s\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u0026gt; Time display resolution 0.01 seconds, time accuracy 0.01%, measurement range 0.01-9999.99 seconds\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u0026gt; Temperature stability ±0.01°C, the test temperature can be as high as 150°C and as low as -40°C\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSimple operation and convenient use\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe user only needs to start the pre-edited measurement method after adding the sample to the viscosity tube. The subsequent measurement process, such as: constant temperature, sample lifting, timing, draining, cleaning, calculation, reporting, etc. can be automatically completed, saving Precious time of experimenters.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eHigh precision glass viscometer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eVISCO 370 series are equipped with high-precision glass viscometers. Users can choose various types of high-precision viscometers that meet ISO, ASTM, DIN and other standards, and different capillary inner diameters, including: Ubbelohde viscometer, Cannon-Fenske viscometer, Oswald viscometer, micro viscometer, dilution viscometer, etc.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePowerful software functions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe Windows software has powerful functions, clear operation logic, and visualized measurement process. Bad values can be automatically removed. There are many built-in standard calculation formulas, and custom formulas can also be made according to known parameters to meet the personalized calculation needs of users. In addition, the system also supports intrinsic viscosity measurement by extrapolation, which requires additional software. For more information, please contact Chemtron.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eHigh precision transparent viscosity bath\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAccording to experimental needs, Chemtron can provide two different temperature control devices with temperature stability of ±0.03 (CT series) and ±0.01 (DT series). According to different test positions, two or four transparent viscosity baths can be provided. In addition, special viscosity baths can also be provided, such as: ultra-low temperature transparent viscosity baths, high temperature viscosity baths, four-position, six-position viscosity baths, etc. For viscosity requirements close to room temperature, it is recommended to be equipped with a cooling circulator.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eAutomatic cleaning function\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eUsers can choose single-solvent or dual-solvent cleaning units according to their needs. When the sample measurement is finished, the syringe pump will automatically add a certain amount of solvent for cleaning and drying, minimizing the chance of direct contact between operators and chemical reagents.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003etesting report\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAfter each measurement, it will be named with the measurement date and time, and PDF and Excel reports will be automatically formed.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eTechnical Parameters:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable border=\"1\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003emodel\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eVISCO 370 EZ\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eVISCO 370\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003etiming range\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e\u003cspan\u003eUp to 9999.99 seconds\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003etiming resolution\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e\u003cspan\u003e0.01 seconds\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eTiming accuracy\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e\u003cspan\u003e±1 digit (0.1%)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003e\n\u003cp\u003e\u003cspan\u003eMeasuring range\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e\u003cspan\u003ePressure method: 0.35~1800mm2\/s(cSt)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e\u003cspan\u003eVacuum method: 0.35~5000mm2\/s(cSt)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eMeasurement parameters\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eThe time it takes for the liquid to flow through the capillary\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eLiquid level detection method\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003ePhotoelectric method (thermal conductivity method is optional)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003ePhotoelectric method \/ thermal conductivity method\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003ePC software\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eWinVisco \/ Dilution 370\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eWinVisco 4 \/ Dilution 370\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003elanguage\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eEnglish, German\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eChinese, English, German, French, Spanish\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eWhether to support extrapolation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e\u003cspan\u003eyes\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eBath temperature monitoring\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e\u003cspan\u003eyes\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eUser Management\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e\u003cspan\u003eThree-level user rights management\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eMeasurement Parallelism Management\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e\u003cspan\u003eBad values are automatically eliminated and automatically added to the test\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eMeasurement methods\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e\u003cspan\u003eCan be edited, stored and recalled\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eCalculation formula\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e\u003cspan\u003eBuilt-in standard calculation formula, you can also customize the formula\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003ePump pressure control\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e\u003cspan\u003eautomatic control\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eConstant temperature time\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e\u003cspan\u003e0~20 minutes\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eMaximum number of measurements for a single sample\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e\u003cspan\u003eup to 10 times\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eConnection and communication\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eRS-232\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eZ multi-support measurement position\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e1~4 digits ( WinVisco ) \/ 1~2 digits (Dilution 370)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e1~8 digits (WinVisco 4) \/ 1~2 digits (Dilution 370)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003etesting report\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e\u003cspan\u003e.pdf format and .csv format\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003ecleaning method\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eYou can choose the next sample rinse (manual), single \/ dual solvent cleaning (automatic). The volume of cleaning solution, draining time and drying time can be set by software\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eIn addition to all the cleaning functions of WinVisco , WinVisco 4 can quickly add or delete custom cleaning and drying processes.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eshape design\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eCompact modular design, more space-saving\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eSpace Modular Design\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eReagent consumption\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eThe special design of routine consumption pipeline saves\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eRegular dosage\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eWhether to support LEMS\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eCan't\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eCan\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eambient temperature\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e\u003cspan\u003e+10~+40℃\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eenvironment humidity\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e\u003cspan\u003eRelative humidity up to 85%\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eVoltage\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e\u003cspan\u003e220V\/50Hz\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"ChemTron","offers":[{"title":"VISCO 370 EZ","offer_id":48072277229790,"sku":null,"price":99999.0,"currency_code":"USD","in_stock":true},{"title":"VISCO 370","offer_id":48072277262558,"sku":null,"price":99999.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/0636\/3870\/files\/1_be2127bd-fce5-4292-89f1-7c0ab65edb56.jpg?v=1775717986","url":"https:\/\/www.ltprocess.com\/products\/chemtron-visco-370-automatic-kinematic-viscosity-measurement-system","provider":"Instrument Trading Center","version":"1.0","type":"link"}