{"product_id":"chemtron-visco-170-semi-automatic-kinematic-viscosity-measurement-system","title":"ChemTron VISCO 170 Semi-Automatic Kinematic Viscosity Measurement System","description":"\u003ch3\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003ePlease Contact Us for the Best Quote and to Confirm Delivery Time\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch3\u003eVISCO 170 Semi-Automatic Kinematic Viscosity Measurement System\u003c\/h3\u003e\n\u003cp\u003eVisco 170 is an automatic timing device specially used for measuring absolute viscosity and relative viscosity by glass capillary method. It is easy to operate and can store data. It is a good helper in viscosity measurement experiments!\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u0026gt; Different from VISCO 370, VISCO 170 is more suitable for the experimental needs of less intensive daily testing but also requires precise viscosity measurement. It is a semi-automatic viscosity testing system specially used for measuring absolute viscosity and relative viscosity by glass capillary method. Easy to operate, economical and affordable, it is a good helper in viscosity measurement experiments!\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u0026gt; Introduction to the degree of automation: the operator can add the sample to be tested into the viscosity tube through the sampling funnel. After the constant temperature is over, use the manual suction pump (or pressure pump) to raise the liquid level. During the process of the liquid level falling, the equipment will automatically time the test. After that, the time is automatically sent to the computer for data processing and storage. After the measurement, add the cleaning agent to the viscometer, and let the cleaning agent wash the viscometer through the manual pump. Then dry it with a low boiling point solvent, or clean the inner wall of the capillary by rinsing the next sample. The liquid in the tube can be discharged into the waste liquid bottle by starting the vacuum pump through the foot switch. The whole operation process is safe and convenient, which greatly reduces the chance of the operator contacting with chemical reagents.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u0026gt; No need to disassemble the viscosity tube, automatic timing measurement, manual sample injection, manual operation cleaning, manual operation to discharge waste liquid, can directly read the time value, and then calculate the viscosity value by hand, or use the standard viscosity test software to automatically obtain the time value , and automatically obtain the viscosity value according to the embedded formula, and up to four semi-automatic measuring positions can be installed.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u0026gt; Can be set through the host screen: sample number, viscometer number, time\/date, measurement times and other information\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u0026gt; In addition to connecting to PC software, VISCO 170 also supports independent measurement after offline, and relevant data can be stored in U disk\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u0026gt; Labeling kit includes: VISCO 170 host, transparent viscosity bath, manual injection kit, cleaning kit, software and data lines. Capillary viscometers are selected according to specific samples and experimental needs\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u0026gt; Optional unit: Printer\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eTechnical Parameters\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable border=\"1\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003emodel\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eVISCO 170\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003edisplay screen\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eLCD display\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003etiming range\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e0.01~999.99 seconds\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003etiming resolution\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e0.01 seconds\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eTiming accuracy\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e±0.01s\/±1 digit; but the accuracy is not more than 0.1%\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eViscosity measurement range\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e0.35-10000mm2\/s(cSt)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eOperating temperature\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eThe Z height is 100°C (150°C model is optional )\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eMeasurement parameters\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eThe time it takes for the liquid to flow through the capillary\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eLiquid level detection method\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003ePhotoelectric method, relying on the concave liquid surface formed by the liquid in the capillary to change the refraction of light, trigger and terminate the timing\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003ePC software\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eWinVISCO 170\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eCalculation formula\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eSupport multiple calculation formulas\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eSupport multiple calculation formulas\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eVacuum method (suction hand pump) \/ pressure method (pressure hand pump)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eConnection and communication\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eUSB-A ( Printer, U- disk ), USB-B (PC, Printer and U -disk )\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eReagent consumption\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eRegular dosage or micro dosage (support micro glass viscometer)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eambient temperature\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e10~40℃\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eenvironment humidity\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eAt 31°C , the humidity is less than 80% ; at 40°C , the humidity is less than 50%\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eVoltage\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eAC100~240V to DC9V\/550mA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eApplicable viscometer\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eThree-tube Ubbelohde viscometer ( DIN , ISO , ASTM , Micro ) and micro Oswald viscometer\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"ChemTron","offers":[{"title":"Default Title","offer_id":48072274084062,"sku":null,"price":99999.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/0636\/3870\/files\/1_bfaf21f6-512e-497f-b388-02cde0222d67.jpg?v=1775717773","url":"https:\/\/www.ltprocess.com\/products\/chemtron-visco-170-semi-automatic-kinematic-viscosity-measurement-system","provider":"Instrument Trading Center","version":"1.0","type":"link"}