{"product_id":"chemtron-lab-gas-generator-nm-plus-series-hydrogen-generator-nmh2-400plusplease-contact-us-for-the-best-quote-and-to-confirm-delivery-time","title":"ChemTron Lab Gas Generator NM plus series hydrogen generator NMH2- 400Plus(Please Contact Us for the Best Quote and to Confirm Delivery Time)","description":"\u003ch3\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003ePlease Contact Us for the Best Quote and to Confirm Delivery Time\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch3\u003eNM PLUS 400 Hydrogen Generator\u003c\/h3\u003e\n\u003cp\u003eFlow rate 250 ml\/min, Purity 99.99996%\u003c\/p\u003e\n\u003ch3 class=\"fl\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eNM PLUS 400 HYDROGEN GENERATOR\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDESCRIPTION\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe Chemtron Gas NM Plus hydrogen generator offers the optimum combination of safe operation, reliability and performance. Designed as a hazard free alternative to high-pressure cylinders, all that is required is deionized water and a standard electrical supply for weeks of continuous operation.\u003c\/p\u003e\n\u003cp\u003eUtilizing our proprietary Proton Exchange Membrane (PEM) inside a 100% titanium cell provides superior generator performance and cell longevity. The permeation membrane drying system eliminates the requirement for desiccant cartridges along with the associated downtime and cost. The final purification stage uses a no maintenance cold dual dynamic regeneration system which increases the purity to +99.99996%. Innovative software control allows unrivaled operational performance and safety as well as the additional options of auto water feed, remote networking and cascading for built in redundancy.\u003c\/p\u003e\n\u003cp\u003eWith a maximum output capacity of 1350 mL\/min, one generator can supply up to 33 GCs. The compact design allows the generator to be installed directly in the laboratory eliminating the requirement for long gas lines and guaranteeing the delivery of high purity gas to your instruments.\u003c\/p\u003e\n\u003cp\u003eA sophisticated control system connected to an easy to use touch screen control continuously monitors vital operating parameters to ensure a safe and consistent performance. Built in sensors will shut the generator down if internal\/external leaks are present, contaminated water, low water or over pressure. This is why Chemtron Gas generator meet the strict safety guidelines to be certified for CE, FCC and MET (CSA and UL compliant).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eINCREASE EFFICIENCY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA constant gas supply with a guaranteed purity, eliminates interruptions of analyses to change cylinders and reduces the amount of instrument re-calibration required.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIMPROVE SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eGas is produced on demand, which allows for the safe use of the hydrogen generator when cylinders are prohibited or regarded as potentially dangerous. Sophisticated software control and full alarm capability, including for hydrogen leaks, gives the user full control of the gas supply.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eENHANCE RESULTS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eHydrogen as a carrier gas is faster and more sensitive than expensive helium, with run time savings of 25% to 35% without a decline in resolution. The use of hydrogenas a carrier gas allows lower temperature elution, thus extending the life of thechromatograph column.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eENHANCE PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eGas generator can be installed in the laboratory close to the instrument, eliminating the need for long gas lines from external cylinder supplies. A constant guaranteed high purity gas supply improves stability and ensures greater reproducibility of results.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eProduces a continuous supply of H2 | On-demand supply 24\/7 | Flow rate: 100 to 1350 mL\/min | Purity: +99.99996% | Pressure: 11 barg (160 psig) | Proprietary 100% titanium cell technology | Unique permeation membrane drying system | Cold dual dynamic regeneration dryer | USB connectivity | 2-year complete cell and product warranty | Easy to install, operate and maintain.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBENEFITS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEliminates dangerous high pressure cylinders helping to keep your employees safer | Removes the logistics, inconvenience, downtime and costs of a cylinder system | Flow capacity and purity to match your specific instrument demands | Ideal for all GC detector applications | Meet and exceeds the requirements for the most demanding GC applications | Superior hydrogen production with reliable long life cell | Minimal maintenance - low cost of ownership | PC monitoring for maintenance, diagnostics and remote connection | Peace of mind | Improve your laboratory work flow and productivity.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOPTIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eI\/O board | Remote control software (RS232 or USB) | Cascading hardware (standard or high purity) | Automatic water refill.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGC APPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u0026gt; GC carrier gas\u003c\/p\u003e\n\u003cp\u003e\u0026gt; GC\/MS carrier gas\u003c\/p\u003e\n\u003cp\u003e\u0026gt; GC fuel gas\u003c\/p\u003e\n\u003cp\u003e\u0026gt; GC-ELCD \u0026amp; HALL reaction gas\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eANALYZER APPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u0026gt; Total Hydrocarbon Analyzer (THA) fuel gas\u003c\/p\u003e\n\u003cp\u003e\u0026gt; Chemisorption\/ Physisorption measurement gas\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSPECTROSCOPY APPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u0026gt; ICP-MS Collision cell reaction gas\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOTHER LAB APPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u0026gt; Chemical Vapor Deposition Instrumentation (CVD) aid deposition process \u0026gt; Plasma Cleaning Instrumentation (UCP)\u003c\/p\u003e\n\u003cp\u003e\u0026gt; High Efficiency Process Gas\u003c\/p\u003e\n\u003cp\u003e\u0026gt; Hydrogenation Reactors\u003c\/p\u003e\n\u003cp\u003e\u0026gt; Hydrogen Fuel Cells\u003c\/p\u003e\n\u003cp\u003e\u0026gt; Weather Balloon Filling\u003c\/p\u003e\n\u003cp\u003e\u0026gt; Electronic Nose (eNOSE)\u003c\/p\u003e\n\u003cp\u003e\u0026gt; 3-D Chromatography\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical parameter\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable border=\"1\" cellspacing=\"0\" class=\"Table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eModels\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNMH2- 400Plus\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eFlow rate (ml\/min)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e400\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePurity\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e＞ 99.99996%\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eDew point at 7 barg (100 psig)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-73 ℃ (-99.4 ℉ )\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOutlet pressure barg (psig)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e1.4 to 11 (20 to 160)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eTechnology\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ePEM (Proton Exchange Membrane) - 100% Titanium cell\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eDrying system\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNo Maintenance Cold Dual Dynamic Regeneration System\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eDeionized water quality\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eMinimum \u0026lt; 1 micro S\/cm @25ºC - 1 Mohm-cm @25ºC - ASTM II Recommended \u0026lt; 0.2 microS\/cm @25ºC - 5 Mohm-cm @25ºC - ASTM II\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eInternal water tank (liters)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2.5\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eSafety\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eAutomatic shut down - internal\/external hydrogen leak, overpressure and low water\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eDisplay\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eTouch screen with operating parameters, system status and safety alarms\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eLED indicators\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ePower on\/off, system ready, errors\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eInterface\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eUSB mod A\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eElectrical supply\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e110-120V 60Hz \/ 220-240V 50Hz\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePower consumption (watts)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e210\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eDimensions mm (inches)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e230W x 507H x 370D (9W x 19H x 15D)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWeight kg (lbs)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e15 (33)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eShipping dimensions mm (in)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e580W x 570H x 400D (22.8W x 22.4H x 15.7D)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eShipping weight kg (lbs)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e19 (42)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOperating temp ℃ ( ℉ )\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e15 to 35 (59 to 95)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOutlet connection\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e1\/8\" Compression\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCertification\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eCE, FCC, MET (UL and CSA compliant)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003eOPTIONS\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eAuto water refill\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eContinuous water feed from an external water supply\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCascading\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eUp to 10 units – built in redundancy for guaranteed up-time\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eInterface\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eRS232\/RS485, external contacts, PC control and intranet\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"ChemTron","offers":[{"title":"Default Title","offer_id":47889641767134,"sku":null,"price":99999.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/0636\/3870\/files\/1_16c3514f-5539-43ac-af37-3da118f7d001.jpg?v=1770707714","url":"https:\/\/www.ltprocess.com\/products\/chemtron-lab-gas-generator-nm-plus-series-hydrogen-generator-nmh2-400plusplease-contact-us-for-the-best-quote-and-to-confirm-delivery-time","provider":"Instrument Trading Center","version":"1.0","type":"link"}